Description
Antimicrobial Capabilities & More…
- Removes up to or more than 99.99% of Bacteria, Virus, and Cysts
- NASA-derived technology
- Greater dirt holding capacity – 100x greater than other conventional filters
- Pleated construction yields high flow rates and low pressure drop
- Minimizing the risk of Legionella by adhering to national guidance
- Lasts for up to 75,000 gallons of water!
Filtration Power that Competes with Top Technologies on the Market!
Contaminants | HydroTAC® Antimicrobial Filter | RO | Particulate Cartridges |
Carbon Block |
Ultra Violet |
Bacteria |
⊗ |
× |
× |
||
Bromine |
× |
||||
Chemical Reduction |
× |
× |
|||
Chromium VI |
⊗ |
× |
|||
Colloids |
⊗ |
× |
× |
× |
|
CTO |
× |
||||
Cysts |
⊗ |
× |
× |
× |
× |
Dissolved Salts |
× |
||||
Endotoxins |
⊗ |
× |
|||
Ferric Iron |
⊗ |
× |
|||
Iodine | |||||
LEAD |
⊗ |
× |
× |
||
Particulates |
⊗ |
× |
× |
× |
|
Polysaccharides (TEP) |
⊗ |
× |
|||
Silica |
⊗ |
× |
|||
Trace Pharmaceuticals |
⊗ |
× |
× |
||
Virus / E. Coli / MS-2 |
⊗ |
× |
× |
||
VOC |
⊗ |
× |
An Effective Duo...
This antimicrobial filter, featuring nano-ceramic technology, in combination with our TAC® filter, can render biologically safer water with the added benefit of scale prevention that will keep your water heating appliances working longer. Unlike an RO membrane that tend to foul quickly, this HydroTAC® duo has high dirt-holding and flow capacity without the need for daily maintenance or backwashing!
SPECIFICATIONS
Rated Flow | Maximum 10 gpm (37.8 lpm) |
Working Temp | 40 – 104 °F (5 – 40 °C) |
Terminal Pressure Drop | 35 psi (2.4 bar); see other filter specs for more details. |
Working Conditions | For indoor use – protection required when installed outdoors. |
Size | 5.5 in x 5.5 in x 13.25 in (140 mm x 140 mm x 337 mm) |
Min Net Weight | 1.2 lbs (0.55 kg) |
Contaminants Reduced | Scale, Sediment, Other Chemicals (See Table Above) |
CONDITIONS FOR USE
pH | 6.5 to 8.5 |
Max Hardness | 75 grains per gallon |
Chlorine | < 3 ppm |
Iron, Ferrous | ≤ 0.3 mg/L |
Manganese | ≤ 0.05 mg/L |
Copper | ≤ 1.3 mg/L |
Oil & Phosphates | Zero* |
Hydrogen Sulfide | Zero* |
*Must be removed prior to HydroTAC®.
NOTICE: New copper should be used for a minimum of one month before placing the unit into service.
NOTICE: Untreated private well water may contain contaminants with levels outside of the operating guidelines. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
LEAD FREE*: The wetted surface of this product contacted by consumable water contains less than 0.25% of by weight.